{"created":"2023-05-15T09:31:34.235503+00:00","id":37,"links":{},"metadata":{"_buckets":{"deposit":"cfd626c2-6344-4163-a80e-0c1f5a5855dc"},"_deposit":{"created_by":12,"id":"37","owners":[12],"pid":{"revision_id":0,"type":"depid","value":"37"},"status":"published"},"_oai":{"id":"oai:kuhs.repo.nii.ac.jp:00000037","sets":["1:12"]},"author_link":["84","85","86","87"],"control_number":"37","item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"70","bibliographicPageStart":"61","bibliographicVolumeNumber":"14","bibliographic_titles":[{"bibliographic_title":"神奈川県立保健福祉大学誌","bibliographic_titleLang":"ja"},{"bibliographic_title":"Journal of University of Human Services","bibliographic_titleLang":"en"}]}]},"item_10002_description_19":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"本研究は、軽度の認知機能低下がみられる患者を対象に、離棟・離院の防止のために作成した、踏切型センサー反応式安全柵(以下、安全柵)の安全性を検証することを目的として、被験者による安全性確認テストを実施した。対象患者に、小型の発信機を所持してもらい、安全柵に近づくとバーが閉じる仕組みである。このため、他の患者への通行の障害にはならず、対象者の離棟を防ぐことができる。\n今回、被験者による歩行テストおよび、車いす使用による走行テストを実施し、安全柵の正常動作が確認されたが、誤動作は見られなかった。しかし、車いす使用によるテストでは、発信機を置く位置により、安全柵のバーの開閉が若干遅れることが確認できた。また、安全柵の耐久性や、対象者以外の患者への対応など問題点も見つかり、今後の課題であることが分かった。今回検証した安全柵は、使用対象者に条件があり使用が限定されているが、使用対象者を適切に選定することや、安全柵の設置場所などを工夫することで、効果的な使用が出来ると考える。今後、対象者を広げて行くために、これらの点を改善して、臨床での使用を検討したいと考える。","subitem_description_language":"ja","subitem_description_type":"Abstract"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"神奈川県立保健福祉大","subitem_publisher_language":"ja"}]},"item_10002_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA12047903","subitem_source_identifier_type":"NCID"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1349-4775","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"松戸, 典文","creatorNameLang":"ja"},{"creatorName":"マツド, ノリブミ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"84","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"香川, 高広","creatorNameLang":"ja"},{"creatorName":"かがわ, タカヒロ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"85","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Matsudo, Noribumi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"86","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kagawa, Takahiro","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"87","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-05-26"}],"displaytype":"detail","filename":"07松戸ら.pdf","filesize":[{"value":"1.4 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"07松戸ら","objectType":"fulltext","url":"https://kuhs.repo.nii.ac.jp/record/37/files/07松戸ら.pdf"},"version_id":"89771578-6a6f-4429-afb6-097b89f5c536"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"離棟・離院","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"防止機器","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"認知機能低下","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"Escape from the ward or hospital","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"prevention gate","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Decrease of the cognitive function","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"軽度認知機能低下患者の離棟・離院防止機器の安全性の検証","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"軽度認知機能低下患者の離棟・離院防止機器の安全性の検証","subitem_title_language":"ja"},{"subitem_title":"Verification of safety of the prevention gate for the patient who escape from the ward or hospital because of slight cognitive dysfunction","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"12","path":["12"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-05-26"},"publish_date":"2017-05-26","publish_status":"0","recid":"37","relation_version_is_last":true,"title":["軽度認知機能低下患者の離棟・離院防止機器の安全性の検証"],"weko_creator_id":"12","weko_shared_id":-1},"updated":"2023-06-16T06:36:03.179644+00:00"}