{"created":"2023-05-15T09:31:34.861404+00:00","id":50,"links":{},"metadata":{"_buckets":{"deposit":"4204541b-dacc-44e5-807e-acb433f19b0e"},"_deposit":{"created_by":12,"id":"50","owners":[12],"pid":{"revision_id":0,"type":"depid","value":"50"},"status":"published"},"_oai":{"id":"oai:kuhs.repo.nii.ac.jp:00000050","sets":["1:13"]},"author_link":["84","99"],"control_number":"50","item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"47","bibliographicPageStart":"39","bibliographicVolumeNumber":"15","bibliographic_titles":[{"bibliographic_title":"神奈川県立保健福祉大学誌","bibliographic_titleLang":"ja"},{"bibliographic_title":"Journal of Kanagawa University of Human Services","bibliographic_titleLang":"en"}]}]},"item_10002_description_19":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"本研究では、手指巧緻性や握力の低下した患者が使用できるように、反応感度が調整可能なナースコールシステムの開発を行った。本システムは、①呼び出しボタン、②コントロールユニット、③PC(パソコン)、④ブザーの4つの機器で構成されている。呼び出しボタンは「ゴム球型」と「フィルム型圧力センサ」の2種類を作成した。それぞれの呼び出しボタンに圧力を加えると、圧力センサが信号を出力して、コントロールユニットを経て圧力データとしてPCへ入力される。予めPC画面上で設定した反応閾値を超えた場合、報知命令信号を発し、ブザーが鳴る仕組みである。ブザーによる機器性能テストと、実際に使用されている病院のナースコールシステムを利用した機器テストを実施したが、何れも正常に作動しており不具合や誤作動はなかった。今後、さらに耐久性を強化し、小型化を図り、利便性を向上させて、臨床での使用に繋げていきたい。","subitem_description_language":"ja","subitem_description_type":"Abstract"}]},"item_10002_heading_23":{"attribute_name":"見出し","attribute_value_mlt":[{"subitem_heading_banner_headline":"資料","subitem_heading_language":"ja"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"神奈川県立保健福祉大学","subitem_publisher_language":"ja"}]},"item_10002_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA12047903","subitem_source_identifier_type":"NCID"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1349-4775","subitem_source_identifier_type":"ISSN"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"松戸, 典文","creatorNameLang":"ja"},{"creatorName":"マツド, ノリブミ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"84","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"香川, 高弘","creatorNameLang":"ja"},{"creatorName":"カガワ, タカヒロ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"99","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-06-18"}],"displaytype":"detail","filename":"05松戸ら.pdf","filesize":[{"value":"1.2 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"05松戸ら","objectType":"fulltext","url":"https://kuhs.repo.nii.ac.jp/record/50/files/05松戸ら.pdf"},"version_id":"b393dc94-1880-4a36-a838-9c0b350f54f5"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"弱い握力|ナースコール|反応感度","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"weak grip strength|nurse call|reaction sensitivity","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"握力の弱い患者が使用できるナースコールの開発に向けた取り組み:反応感度が調整可能なナースコールシステムの機器性能の検証","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"握力の弱い患者が使用できるナースコールの開発に向けた取り組み:反応感度が調整可能なナースコールシステムの機器性能の検証","subitem_title_language":"ja"},{"subitem_title":"Efforts towards the development of“ nurse call” that patients with weak grip strength can use : Verification of instrument performance of nurse call system with adjustable response sensitivity","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"12","path":["13"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-06-18"},"publish_date":"2018-06-18","publish_status":"0","recid":"50","relation_version_is_last":true,"title":["握力の弱い患者が使用できるナースコールの開発に向けた取り組み:反応感度が調整可能なナースコールシステムの機器性能の検証"],"weko_creator_id":"12","weko_shared_id":-1},"updated":"2023-06-16T06:02:44.348228+00:00"}